News

Several Mistakes In The Maintenance Of Mechanical Seals For Pumps

Publish Time: Author: Site Editor Visit: 49

Sanitary Rotary Lobe Pump The greater the spring compression, the better the sealing effect

In fact, it is not the case. Excessive spring compression can cause rapid wear and instant burning of the friction pair; excessive compression causes the spring to lose the ability to adjust the end face of the dynamic ring, resulting in seal failure.

The tighter the dynamic ring seal, the better

In fact, too tight a dynamic ring seal is harmful rather than beneficial. First, it aggravates the wear between the seal and the sleeve, causing premature leakage; second, it increases the resistance to axial adjustment and movement of the dynamic ring, and cannot be adjusted in time when the working conditions change frequently; third, the spring is easily damaged due to excessive fatigue; fourth, it causes the dynamic ring seal to deform, affecting the sealing effect.

The tighter the static ring seal, the better

The static ring seal is basically in a static state, and the sealing effect will be better if it is relatively tight, but over-tightening is also harmful. First, it causes excessive deformation of the static ring seal, affecting the sealing effect; second, the static ring material is mostly graphite, which is generally brittle, and excessive force can easily cause fragmentation; third, it is difficult to install and disassemble, and it is easy to damage the static ring.

The tighter the impeller lock nut, the better

Among mechanical seal leakage, leakage between the sleeve and the shaft (inter-shaft leakage) is more common. It is generally believed that inter-shaft leakage means that the impeller lock nut is not tightened. In fact, there are many factors that lead to inter-shaft leakage, such as failure of the inter-shaft gasket, offset, impurities in the shaft, large shape and position errors at the fit between the shaft and the sleeve, damage to the contact surface, gaps between the components on the shaft, and too long shaft head threads. All of these will lead to inter-shaft leakage. Excessive tightening of the lock nut will only cause the inter-shaft gasket to fail prematurely. On the contrary, moderately tightening the lock nut will keep the inter-shaft gasket always in a certain compression elasticity. During operation, the lock nut will automatically lock in time to keep the shaft in a good sealing state.

New is better than old

Relatively speaking, the effect of using a new mechanical seal is better than the old one, but if the quality or material of the new mechanical seal is not selected properly, the large size error will affect the sealing effect; in polymeric and permeable media, if the static ring is not excessively worn, it is better not to replace it. Because the stationary ring is in a static state in the stationary ring seat for a long time, the polymer and impurities are deposited as one, which plays a better sealing role.

It is better to dismantle and repair than not to dismantle

Once a mechanical seal leaks, people are eager to dismantle and repair it. In fact, sometimes the seal is not damaged, and the leakage can be eliminated by adjusting the working conditions or adjusting the seal appropriately. This can not only avoid waste but also verify one's own fault judgment ability, accumulate maintenance experience and improve the quality of maintenance.

Several Mistakes In The Maintenance Of Mechanical Seals For Pumps

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.