News

How To Deal With The Pump Flow Rate Not Reaching The Rated Flow Rate

Publish Time: Author: Site Editor Visit: 156

Various common problems will inevitably occur during the use of Emulsification Pump, such as the problem that the water pump flow rate cannot be reached suddenly. So how to solve this problem of flow rate not being reached?

Solutions to the problem that the pump cannot reach the rated flow rate:

1. The installation height of the water pump is too high, and the depth of the impeller immersed in the water source is not enough, resulting in a decrease in the suction volume of the water pump, which naturally leads to a decrease in the water output of the water pump;
Solution: Modify the allowable deviation of the installation elevation of the water pump, and do not enter and expand it at will;

2. The water pump is in the opposite direction;
Solution: Before starting the water pump, check whether the direction of the water pump motor is consistent with the direction of the water pump. If not, check whether the phase sequence of the power supply of the water pump motor has changed;

3. The water pump outlet valve cannot be opened;
Solution: Check the water pump valve and maintain it regularly;

4. The water outlet pipe is not smooth or blocked;
Solution: Clean the blockage on the inner wall of the pipe and the impeller, and clean the debris in the water source pool from time to time;

5. The wear-resistant ring at the lower end of the water pump is severely worn or blocked;
Solution: Replace the wear-resistant ring at the lower end and clean the blockage in the pump body;

6. The density of the pumped liquid is too high or the viscosity is too high;
Solution: Re-equip the pump with a pump that matches the pump medium;

7. The impeller is detached or damaged;
Solution: Reinstall or replace the impeller;

8. Multiple pumps share the same pipeline output, and there is no one-way valve installed or the one-way valve is not sealed tightly;
Solution: Install a one-way valve and replace the one-way valve seal.

How To Deal With The Pump Flow Rate Not Reaching The Rated Flow Rate

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.